| Performance Data |
|
|
| |
|
|
|
Thermal current Rating (100%): |
|
Up to 80 Amperes |
|
|
|
|
|
Reduced Duty Cycle Rating: |
|
30% - 150 Amperes |
|
|
|
40% - 125 Amperes |
|
|
|
50% - 115 Amperes |
|
|
|
60% - 105 Amperes |
|
|
|
70% - 70% - 95 Amperes |
|
|
|
|
|
Typical Inductive Fault Currents that can be Ruptured |
|
5mS Time Constant: |
|
500 Amperes at 60V D.C. |
|
|
|
|
|
Maximum Recommended Contact
Voltages: |
|
48V D.C. |
|
|
|
|
|
Typical Voltage Drop across
New Contacts: |
|
15mV |
|
|
|
|
|
Mechanical Life: |
|
>3,000,000 operations |
|
|
|
|
|
Coil Power Dissipation |
|
|
|
Intermittently Rated types
(50% Duty Cycle): |
|
10 - 14 Watts |
|
Intermittently Rated types
(25% Duty Cycle): |
|
14 - 21 Watts |
|
Continuously Rated types: |
|
5 - 7 Watts |
|
|
|
|
|
Maximum Pull-in Voltage (Coil at 20°C) |
|
|
|
Intermittently Rated types: |
|
60% of rated voltage |
|
Continuously Rated types: |
|
66% of rated voltage |
|
|
|
|
|
Typical Drop-out Voltage |
|
10 - 25% of rated voltage |
|
|
|
|
|
Typical Pull-in Time |
|
|
|
Normally Open Contacts to
Close: |
|
15mS |
|
|
|
|
|
Typical Drop-out Time (Normally Open Contacts to Open) |
|
Without Suppression: |
|
6mS |
|
With Diode Suppression: |
|
35mS |
|
|
|
|
|
Typical Main Contact Changeover Time |
|
|
|
Normally Closed to Normally
Open: |
|
6mS |
|
Normally Open to Normally
Closed: |
|
6mS |
|
|
|
|
|
Typical Contact Bounce
Period: |
|
3mS |
|
|
|
|
|
|
|
 |