Heavy Duty DC Battery Disconnecting Switches
The "ED" and "SD" ranges of Disconnecting switches have been designed to
provide a rapid means of disconnecting batteries or other power supplies
in the event of serious electrical faults. The switches are primarily
intended for use with battery powered vehicles but are also suitable for
use with static power systems.
All types are capable of safety rupturing full
load battery currents in the event of an emergency.
|
|
|
|
|
|
|
|
ED and SD series of Emergency Disconnecting
Switches |
|
|
|
|
Catalog No. |
|
Description |
|
Maximum Thermal |
|
|
|
|
|
Current Rating |
|
ED125 |
|
Manual Disconnect Single Pole On/Off |
|
125 Amperes |
|
ED125L |
|
Manual Disconnect Single Pole On/Off |
|
125 Amperes |
|
|
|
Lockable Version |
|
|
|
ED250 |
|
Manual Disconnect Single Pole On/Off |
|
250 Amperes |
|
ED250L |
|
Manual Disconnect Single Pole On/Off |
|
250 Amperes |
|
|
|
Lockable Version |
|
|
|
ED252 |
|
Manual Disconnect Double Pole On/Off |
|
250 Amperes |
|
ED252L |
|
Manual Disconnect Double Pole On/Off |
|
250 Amperes |
|
|
|
Lockable Version |
|
|
|
ED402 |
|
Manual Disconnect Double Pole On/Off |
|
400 Amperes |
|
ED402L |
|
Manual Disconnect Double Pole On/Off |
|
400 Amperes |
|
|
|
Lockable Version |
|
|
|
SD150 |
|
Combined Manual Disconnect and Line Contactor |
|
125 Amperes |
|
|
|
Single Pole On/Off |
|
|
|
SD150L |
|
Combined Manual Disconnect and Line Contactor |
|
125 Amperes |
|
|
|
Single Pole On/Off - Lockable Version |
|
|
|
SD250 |
|
Combined Manual Disconnect and Line Contactor |
|
250 Amperes |
|
|
|
Single Pole On/Off |
|
|
|
SD250L |
|
Combined Manual Disconnect and Line Contactor |
|
250 Amperes |
|
|
|
Single Pole On/Off - Lockable Version |
|
|
|
|
|
|
|
|
|
Control Units |
|
Solid state devices to time or
control switching to limit power consumption and |
|
prevent coil overheating.
|
|

|
|
Controller Units for Albright Contactors |
|
|
|
Catalog No. |
|
Description |
|
TU150 |
|
Time delay Unit - to delay the operation of an electrical circuit for a
preset period. |
|
CC58 |
|
chopped Coil Unit - This controller is used to reduce the power
consumption of |
|
|
|
a standard contactor coil. |
|
ML52 |
|
Magnetically Latched Unit - This controller automatically alternates the
supply |
|
|
|
polarity every time the unit is energised. |
|
ML53 |
|
Magnetically Latched Unit - This controller has two electrical inputs, the
one |
|
|
|
will always give an "on" pulse and the other will give an "off" pulse. |
|
|
|
 |