| Performance Data |
|
|
| |
|
|
|
Thermal current Rating (100%): |
|
800 Amperes |
| |
|
|
| Overload Currents that can be ruptured |
|
Resistive Load: |
|
1200 Amperes at 60V D.C. |
| |
|
|
| Maximum Recommended Contact |
|
|
|
Voltage: |
|
60V D.C. |
| |
|
|
| Typical Voltage Drop across Contacts |
|
|
per 100 Amperes: |
|
15mV |
| |
|
|
|
Mechanical Life: |
|
>1,000,000 operations |
| |
|
|
|
Coil Power Dissipation: |
|
13 to 25 Watts |
| |
|
|
| Maximum Pull-in Voltage (coil at 20°C) |
|
|
Continuously rated type: |
|
66% of the rated voltage |
| |
|
|
|
Typical Drop-out Voltage: |
|
10 to 30% |
| |
|
|
| Typical Pull-in Time |
|
|
|
Normally Open contacts to
close: |
|
70mS |
| |
|
|
| Typical Drop-out time (Normally Open
contacts to open) |
|
Without Suppression: |
|
10mS |
|
With Diode Suppression: |
|
80mS |
|
With Diode & Resistor (value
dependent): |
|
30mS |
| |
|
|
| Auxiliary Contacts Switching Capabilities |
|
|
|
Resistive Load: |
|
5A at 24V D.C. |
| |
|
2A at 48V D.C. |
| |
|
0.5A at 240V D.C. |