Moulded
Case Circuit Breaker (MCCBs)
Types 250AF Specifications |
MCCBs
Specifications for
Frame Size 250AF
|
Frame Size |
250AF |
| Frame Type (AF) |
GBN |
GBH |
GBL |
GBL (Electronic Trip) |
| Breaking capacity (kA), Icu at 415V AC |
35 |
50 |
85 |
85 |
| Number of poles |
2,3,4 |
2,3,4 |
2,3,4 |
3 |
|
Type |
2 pole |
GBN202 |
GBH202 |
GBL202 |
|
|
|
|
|
3 pole |
GBN203 |
GBH203 |
GBL203 |
GBL53E |
GBL103E |
GBL203E |
|
|
4 pole |
GBN204 |
GBH204 |
GBL204 |
|
|
|
| Rated current (A) |
125, 160, 200, 250 |
50 |
100 |
250 |
| In at 40°C |
Thermally adjustable; |
Electronically adjustable; |
|
|
|
(0.8 - 0.9 - 1.0) x In |
(0.5-0.6-0.7-0.8-0.9-1.0) x In |
|
|
|
|
|
|
|
|
|
| Technical data conforming to
IEC/EN60947-2 |
| Rated operational voltage (V),
Ue(50/60Hz) |
600 |
600 |
600 |
600 |
| Rated operational voltage (V),
Ue(DC) |
250 |
250 |
250 |
- |
| Rated insulation voltage (V)
Ui(50/60Hz) |
690 |
690 |
690 |
690 |
| Rated impulse withstand voltage
(kV), Uimp |
6 |
6 |
6 |
6 |
| Ultimate breaking capacity (kA),
Icu |
|
|
|
|
|
|
|
AC 50/60Hz |
220/240V |
50 |
85 |
125 |
125 |
|
|
380/415V |
35 |
50 |
85 |
85 |
|
|
440/460V |
35 |
50 |
85 |
85 |
|
|
480/500V |
30/22 |
42/35 |
65/50 |
65/50 |
|
|
600V |
18 |
25 |
35 |
35 |
|
DC |
125V |
- |
- |
- |
- |
|
|
250V |
35 |
50 |
85 |
85 |
| Service breaking capacity (%Icu),
Ics |
75 |
75 |
75 |
75 |
| Category of use |
A |
A |
A |
A |
| Endurance |
|
mechanical |
10,000 |
10,000 |
10,000 |
10,000 |
| Number of operation |
electrical |
5,000 |
5,000 |
5,000 |
5,000 |
|
|
|
|
|
|
|
|
|
| Type of trip unit |
|
|
|
|
|
|
Thermal-magnetic release
|
Adjustable-thermal & magnetic |
|
|
|
| Electronic release |
|
|
|
LSIA configuration |
| Pre-alarm via LED |
|
|
|
|
|
|
| Hydraulic-magnetic release |
|
|
|
|
|
|
| Magnetic release only without
thermal trip |
|
|
 |
|
|
|
| Earth leakage protection |
for 3 pole |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Accessories |
| Electrical auxiliaries |
auxiliary switch |
 |
 |
 |
 |
|
|
alarm switch |
 |
 |
 |
 |
|
|
shunt trip |
 |
 |
 |
 |
|
|
undervoltage trip |
 |
 |
 |
 |
|
|
|
|
|
|
|
External accessories
|
manual rotary handle |
 |
 |
 |
 |
|
|
terminal cover |
 |
 |
 |
 |
|
|
Insulation barrier |
 |
 |
 |
 |
|
|
rear connection |
 |
 |
 |
 |
|
|
mechanical interlock |
- |
- |
- |
- |
|
|
remote control |
- |
- |
- |
- |
|
|
|
|
|
|
|
| Dimensions (mm) |
3 pole breaker |
105 (W) x 165 (H) x 86 (D) |
105 (W) x 165 (H) x 86 (D) |
|
|
|
|
|
|
|
| Weight (kg) |
|
2 pole |
1.5 |
1.5 |
1.5 |
|
|
|
3 pole |
1.7 |
1.7 |
1.7 |
1.7 |
|
|
4 pole |
2.1 |
2.1 |
2.1 |
|
|
|
|
|
|
|
|
|
|
| Note:
applicable or available
available as a separate breaker |
|
 |
|